SMALLER VOLUME
HIGH PRODUCTIVITY

The ARCHITECT ci4100 combines ARCHITECT c4000 and ARCHITECT i1000SR instruments − offering lower volume laboratories the enhanced efficiency and productivity employed by larger volume laboratories.

The ARCHITECT ci4100 offers a maximum throughput of up to 900 tests per hour, including 800 clinical chemistry and 100 immunoassay tests. Featuring a load-up capacity of 180 samples with 35 priority positions, the ARCHITECT ci4100 has up to 115 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).

For in vitro diagnostic use only.

 
Description
Methods See c4000 and i1000SR specifications
Maximum Throughput Up to 900 tests/hour
Sample Types See c4000 and i1000SR specifications
Sample Tubes Height: 72-102 mm
Diameter 9.6-16.1 mm
Sample Cup Yes (50 µL dead volume)
Sample Capacity 180
Sample Barcode Types Code 39, Codabar, Interleaved 2 of 5, Code 128
Sample Result Storage 50,000
Sample Volume See c4000 and i1000SR specifications
Automatic Dilution Yes
Sample Probe Carryover ≤0.1 parts per million
Reagent Capacity Up to 115 refrigerated positions plus patented ISE (Na+, K+ and Cl-)
Reagent Type See c4000 and i1000SR specifications
Reagent Onboard Stability See c4000 and i1000SR specifications
Calibration Frequency See c4000 and i1000SR specifications
Sample, Clot and Bubble Detection  Yes 
Reagent Pressure Monitoring See c4000 and i1000SR specifications
Sample Interference Measurement Yes: Hemolysis, Icterus, and Lipemia
System Control Center  1 SCC, with color touchscreen monitor, keyboard and mouse 
Onboard Maintenance Records Yes 
Online Error Code Help Yes  
Host Interface Bidirectional, serial RS-232 interface, host query option available 
Remote Diagnostics AbbottLink 
Dimensions
(H x W x D)

49” x 111” x 36”
125.1 x 281.2 x 90.7 cm

Weight 1,677 lbs 
760.7 kg 
Electrical Requirements See c4000 and i1000SR specifications
Water Requirements See c4000 and i1000SR specifications
Heat Output* See c4000 and i1000SR specifications
Sample Loading RSH
*Values provided represent the typical output in “Running” mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics.
Note: Some of these specifications are based on the combination of the ARCHITECT c4000 and the ARCHITECT i1000SR. For accurate and complete specifications, please refer to the individual operations manual.

DOCUMENTATION

Review a few details about the ARCHITECT ci4100 integrated system in the specifications sheet (PDF, 118 KB).

Download

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.

Do you wish to continue and exit this website?

Yes No

You are about to enter an Abbott country or region specific website.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.

Do you wish to continue and enter this website?

Yes No

You are about to enter an Abbott country or region specific website.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.

Do you wish to continue and enter this website?

Yes No

DO YOU WISH TO CONTINUE AND EXIT THE CORE LABORATORY WEBSITE?

Content is not under the control of corelaboratory.abbott.

Yes No