logo Architect ci8200

LARGE LOAD CAPACITY
CONSISTENT STAT RESULTS

One platform. Multiple benefits. The ARCHITECT ci8200 combines the ARCHITECT c8000 and the ARCHITECT i2000SR to provide clinical chemistry and immunoassay testing in a single integrated system. By delivering fast, high-quality STAT results, the ARCHITECT ci8200 allows for laboratories to handle complex workloads.

The ARCHITECT ci8200 integrated system provides laboratories a single testing module that is specifically designed to improve laboratory efficiency and turnaround time. The ARCHITECT ci8200 offers a maximum throughput of up to 1,400 tests per hour, including 1,200 clinical chemistry and 200 immunoassay tests. Featuring a load-up capacity of 365 samples with 35 priority positions, the ARCHITECT ci8200 has up to 146 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).

For in vitro diagnostic use only.

 
Description
Reaction Method See c8000 and i2000SR specifications
Maximum Throughput Up to 1,400 tests/hour
Sample Types See c8000 and i2000SR specifications
Sample Tubes Height: 72-102 mm
Diameter 9.6-16.1 mm
Sample Cup Yes (50 µl dead volume) 
Sample Capacity 365 
Sample Barcode Types Code 39, Codabar, Interleaved 2 of 5, Code 128
Sample Result Storage 50,000
Sample Volume See c8000 and i2000SR specifications
Automatic Dilution Yes 
Sample Probe Carryover ≤0.1 parts per million 
Reagent Capacity  Up to 146 refrigerated positions plus patented ISE (Na+, K+ and Cl-)
Reagent Type See c8000 and i2000SR specifications
Reagent Onboard Stability  See c8000 and i2000SR specifications
Calibration Frequency See c8000 and i2000SR specifications
Sample, Clot and Bubble Detection Yes 
Reagent Pressure Monitoring See c8000 and i2000SR specifications
Sample Interference Measurement Yes: Hemolysis, Icterus, and Lipemia
System Control Center  1 SCC, with color touchscreen monitor, keyboard and mouse  
Onboard Maintenance Records Yes  
Online Error Code Help Yes 
Host Interface Bidirectional, serial RS-232 interface, host query option available 
Remote Diagnostics AbbottLink 

Dimensions 
(H x W x D)

48" x 127" x 49"
121.9 x 322.6 x 124.5 cm

 Weight

2,447 lbs
1109.9 kg

Electrical Requirements See c8000 and i2000SR specifications
Water Requirements  See c8000 and i2000SR specifications
 Heat Output* See c8000 and i2000SR specifications
Sample Loading RSH + Carousel
*Values provided represent the typical output in “Running” mode for the system processing module and  sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics.  
Note: Some of these specifications are based on the combination of the ARCHITECT c8000 and the ARCHITECT i2000SR. For accurate and complete specifications, please refer to the individual operations manual.

DOCUMENTATION

Review a few details about the ARCHITECT ci8200 integrated system in the specifications sheet (PDF, 118 KB).

Download

You are about to exit the Abbott family of websites for a 3rd party website

Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.

Do you wish to continue and exit this website?

Yes No

You are about to enter an Abbott country or region specific website.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.

Do you wish to continue and enter this website?

Yes No

You are about to enter an Abbott country or region specific website.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.

Do you wish to continue and enter this website?

Yes No

DO YOU WISH TO CONTINUE AND EXIT THE CORE LABORATORY WEBSITE?

Content is not under the control of corelaboratory.abbott.

Yes No